NEW INSTALLATION & RETROFITS
Get code-compliant fire protection installed on schedule with clean workmanship, coordinated trades, and accurate turnover documents. Our union technicians build, retrofit, and commission systems that pass inspections and keep you moving.


WHO WE HELP
We partner with general contractors, construction managers, property managers, facility and safety teams, and owners across Allegheny County. Projects range from core and shell to tenant improvements, change-of-use retrofits, and phased work in occupied buildings near healthcare, campus, industrial, and mixed-use corridors.
We design, install, and retrofit fire protection systems, coordinate with other trades, manage permits and inspections, and deliver complete turnover packages. When schedules are tight, we phase work to keep areas open, pretest systems, and combine inspections to reduce repeat trips.
CITIES SERVED

For installation and retrofit projects in Pittsburgh, we plan work around real site conditions, traffic patterns, and inspection workflows. Downtown routes include PPG Paints Arena, the David L. Lawrence Convention Center, Acrisure Stadium, and PNC Park where crane picks and deliveries require precise windows. Oakland projects near the University of Pittsburgh, Carnegie Mellon University, and UPMC campuses often include quiet hours, ICRA barriers, and phased work across labs and clinical spaces.
We support mixed-use and tech spaces in the Strip District, Lawrenceville, Bakery Square, and Hazelwood Green, as well as industrial corridors along the rivers in the North Shore, SouthSide Works, and Neville Island. Airport-area scopes in Moon and Robinson are staged around security, delivery curfews, and event schedules. Main drains, hydrant flows, and pump runs are timed to avoid rush periods on I-376, I-279, I-579, and the Parkway corridors. Underground tie-ins and backflow approvals are coordinated with PWSA and local water authorities, with locate tickets filed before excavation.
Cold-weather phases include heat tracing checks, enclosure plans, and temporary heat for riser rooms so hydro tests and flushes stay on schedule. We manage AHJ submittals and inspections with local building and fire prevention teams and align pretest dates with the water authority to streamline acceptance.
Downtown Pittsburgh, PA
North Shore, PA
Strip District, PA
Lawrenceville, PA
Shadyside, PA
Oakland, PA
Squirrel Hill, PA
Greentree, PA
McKees Rocks, PA
Bethel Park, PA
Penn Hills, PA
South Side, PA
Mt. Washington, PA
Bloomfield, PA
East Liberty, PA
North Side, PA
Robinson Township, PA
Moon Township, PA
Carnegie, PA
Homestead, PA
Mt. Lebanon, PA
Fox Chapel, PA
SYSTEMS WE INSTALL & RETROFIT
We provide complete installation and targeted upgrades for the systems below.

Design and install sprinkler systems meeting NFPA 13 and 13R.

Engineer standpipe systems and outlets compliant with NFPA 14.

Provide fire pumps, controllers, testing, and startup per NFPA 20.

Install underground mains and backflows per NFPA 24 and codes.
PROJECT TYPES
Comprehensive coverage of new construction, retrofits, and code upgrades.

HOW IT WORKS

We confirm system types, site contacts, and access details. When possible we combine services so you can add fire pump and backflow testing to the same appointment. We set a firm arrival window and offer after hours options on request.

We prepare drawings, hydraulic calculations, and cut sheets where required and submit for AHJ review. Coordination includes ceiling plans, mechanical conflicts, and penetrations. We respond to plan review comments with updates until approved.

Union installers follow site safety rules and keep work areas clean. We coordinate with other trades, verify hangers and bracing, and phase work to match your schedule. Daily communication keeps the GC or owner updated.

We conduct acceptance tests such as hydrostatic tests, main drain and flow tests, alarm function tests, and hood system checks. Your team receives simple training on valves, panels, and testing points before turnover.

You receive as built drawings, a basic operations and maintenance packet, and acceptance test results. We include a limited one year product warranty. If you want ongoing inspections, we set the first calendar.
Pricing is based on drawings or a site survey, device counts, equipment, and schedule requirements. You receive a written, itemized quote before work begins. Scope changes are documented through clear change orders.
Work follows applicable NFPA standards and local code. Reports, tags, and test records are prepared in formats your AHJ prefers. We attend inspections and help resolve comments quickly.
We plan around material availability and trade coordination. Control valves, heads, panels, and devices can have lead times. Early submittals reduce delays. Tell us your milestone dates and we will build the schedule backward.
FAQ
Both. We offer design build and plan and spec installation. We can also value engineer when the goal is a code compliant result with fewer delays.
Yes. We prepare submittals, respond to plan review, schedule tests, and attend inspections until approval.
Small suites can finish in one to two weeks once materials are on site. Larger spaces or complex occupancies take longer. We provide a schedule with milestones before work begins.
Yes. We can connect to central station monitoring and set a testing schedule for weekly or monthly signal checks.
NEED HELP NOW?

1502 Mahoning Ave,
Warren, OH 44483
330-360-1514